Tel:86-10-63718559 / +86 18518316054 / 86-10-63718559
  Current location : Home page > Products > Photoelectrochemical catalytic systems > CEL-SLF-Vertex photoelectrochemical test and analysis system
Click to return to product center  
CEL-SLF-Vertex photoelectrochemical test and analysis system

Model:CEL-SLF-Vertex

Place of Origin:Beijing

Brief introduction:The photocatalytic reaction of semiconductor materials is a catalytic process that takes place at the interface of two conductors with different types (electron and ion) of conductivity and has both photocatalytic and electrocatalytic characteristics.

Contact now

Technical parameters and advantages of CEL-SLF-Vertex photoelectric chemical test and analysis system.


1. good light source stability, better than 0.5%; high integration, the system is integrated in an optical plate, the optical path is stable and easy to transport.

2. optical path is optimized to achieve maximum light output efficiency of 50mw/cm2; spectral range 300-1600nm, output bandwidth continuously adjustable, 0.1~30nm.

3. monochromator is equipped with a special port for nitrogen filling, which is convenient for use in the UV and NIR bands with atmospheric absorption spectrum; the optical room and mechanical drive room are strictly separated to avoid stray light from the latter and the pollution of the optical parts by trace volatilization of lubricating oil; the monochromator body is a one-piece structure of the casting to ensure the stability of the optical system.

4. computer software can realize real-time online control and data acquisition of xenon lamp light source, monochromator, filter wheel, shutter, optical power meter and electrochemical workstation.

5. automatic shutter Shutter is used to control the irradiation time (0.1ms),DK25; shielded darkroom 30cm*30cm*35cm, adjustable height.

6. reaction cell can be selected from the PECK series photoelectric reaction cell, and standard with applicable electrodes.

7. Standard equipped with Admiral Squidstat Plus electrochemical workstation, powerful software functions to achieve full coverage of electrochemical functions, especially in AC impedance EIS test, and can achieve secondary development and upgrading.

8. Standard with CEL-HXF300/HXUV300 series xenon lamp light source, can be used alone, but also with the filter to achieve photoelectric catalysis experiments.

9. The adjustable part of the light source covers the ultraviolet region, visible region, infrared region, there are many kinds of optional light sources, optional light sources are deuterium lamp, iodotungsten lamp, xenon lamp light source, mercury lamp light source, etc., of which xenon lamp is very widely used, and has a continuous full spectrum.


Advantageous features.

Photoelectrocatalytic reaction of semiconductor materials is a catalytic process carried out at the interface of two conductors with different types (electron and ion) conductivity, which has the characteristics of both photocatalysis and electrocatalysis. Photocatalytic method in recent years has received increasing attention to wastewater treatment technology, photolysis of water to produce hydrogen, catalytic reduction of CO2 to organic matter, nitrogen fixation to ammonia, etc., under the action of light and applied electric field, the electron-hole pairs are effectively separated, thus improving the role of catalytic efficiency. cel-SLF-Vertex photoelectric chemical test and analysis system is a photoelectric catalytic system independently developed by CEL-Jinyuan, which can be used with the U.S. Admiral, Germany Zahner, PINE, CHI and other electrochemical workstations, the system can be upgraded and developed twice to solve the customization requirements of customers. The photocatalytic system can achieve continuous wavelength adjustment, and is used in many fields such as material characterization, photoelectricity testing, electrochemical analysis, photocatalysis and IPCE testing.


CEL-SLF-Vertex photoelectrochemical test and analysis system configuration


Light source

CEL-PF300-T8 series xenon lamp light source, CEL-S500 series xenon lamp light source, tungsten halogen lamp light source

Monochromator

CEL-IS151 double grating scanning monochromator, CEL-IS302 three grating scanning monochromator

Filter wheel

Motorized filter wheel IFW6

Accessories

Optical level base plate, coupling joint, converging lens, closed optical path sleeve, etc.

Shutter

Automatic shutter Shutter for irradiation time control (0.1ms), DK25

Sample darkroom

Sample shielded dark room 30cm*30cm*35cm

Reaction cell

PECK series photoelectric reaction cell

Electrodes

Electrode clamp, working electrode, reference electrode, custom electrode

Electrochemical workstation

Admiral (USA), Zahner (Germany), PINE, CHI and other electrochemical workstations


Commonly used optional accessories, there are many auxiliary accessories in the system can help the system more convenient to complete the photoelectric analysis.


1.CEL-NP2000 Intense light power meter / CEL-FZ-A power meter for monitoring the output light optical power density


2. AULTT-P4000 fiber optic spectrometer for monitoring the spectrum of the output light


3. Automatic shutter Shutter for controlling the irradiation time


4. 3D four-probe sample table for placing samples and adjusting the distance precisely


5.5mm liquid crystal fiber/quartz fiber for monochromatic light irradiation


6. Customized optical dark box for the elimination of stray light effects and electromagnetic shielding


7. Optical platform for adjusting the height of each instrument in the system to make the optical path horizontal


8. Electrochemical workstation Electric signal data acquisition


9. Various electrochemical reaction cells for photoelectric reaction